400 New Construction

Windows with Grids

EcoShield Windows

Back

NFRC Testing Chart
Effective Date: May 21, 2013

Thermal Performance Data - 400 Double HungEnergy Star
Glass TypeU-ValueSHGCVLTCRCompliance
DOE - R5 - TripleArgon/Argon - Low E/Low E0.210.190.3571All Zones
ST Energy Star0.280.240.4558All Zones
High Perf. Low E0.320.240.4555SC, S
ClearClear-Air-Clear0.440.510.5346--

 

Thermal Performance Data - 400 Picture WindowEnergy Star
Glass TypeU-ValueSHGCVLTCRCompliance
DOE - R5 - TripleArgon/Argon - Low E/Low E0.200.200.3774All Zones
ST Energy Star0.270.250.4764All Zones
High Perf. Low E0.300.250.4760All Zones
ClearClear-Air-Clear0.440.540.5647--

 

Thermal Performance Data - 400 Rolling WindowEnergy Star
Glass TypeU-ValueSHGCVLTCRCompliance
DOE - R5 - TripleArgon/Argon - Low E/Low E0.230.190.3568All Zones
ST Energy Star0.290.240.4662All Zones
High Perf. Low E0.320.240.4658SC, S
ClearClear-Air-Clear0.450.520.5446--

 